Specifications
Technical data | |
---|---|
Measuring quantity | Standard flow velocity wN based on standard conditions 1) Temperature of medium TM |
Measured medium | Air or nitrogen Optional: biogas, methane, natural gas, argon, CO2, special gases and mixtures and others (on request) |
Measuring range wN | 0 … 10 / 20 / 60 / 90 / 140 / 220 m/s Optional: Customised measuring ranges in steps of 1 m/s |
Lower detection limit wN | 0.1 m/s |
Measuring range TM | -20 … +120 °C |
Measuring accuracy | |
Standard wN | ±(3 % of measured value + [0.4 % of fmr; min. 0.08 m/s]) 2) |
Response time (t90) wN | 10 s (jump of wN from 0 to 5 m/s in air) |
TM (wN > 2 m/s) | ±1 K (10 … 30 °C); ±2 K (remaining measuring range) |
Operating temperature | |
Sensor probe | -20 … +120 °C |
Electronics | -20 … +70 °C |
Storage temperature | -20 … +85 °C |
Material | |
Housing | Aluminium, anodised |
Sensor tube | Stainless steel 1.4571 |
Sensor head | Stainless steel 1.4404 |
Sensor cable (remote sensor) | Jacket TPE, halogen-free |
Compression fitting | Standard: Stainless steel 1.4571, FKM PWIS-compliant: Stainless steel 1.4571, coating DurniCoat (NiP) |
General data | |
Humidity | Measuring mode: Non-condensing (< 95 % RH) |
Operating pressure (max.) | 16 bar (overpressure) |
Display | 4 x Duo-LED (green/red/orange) |
Supply voltage | 24 V DC ± 20 % |
Current consumption | Typical 80 mA (without pulse outputs); max. 200 mA (excluding signal current of pulse output 2 [relay]) |
Analog outputs Type: Auto U / I) | wN, TM 0 … 10 V / 4 … 20 mA (switching of signal characteristic depends on RL) -Voltage output (0 … 10 V): RL ≥ 550 Ω (short-circuit protected) - Current output (4 … 20 mA): RL ≤ 500 Ω - Change-over hysteresis: 50 Ω - CL ≤ 10 nF |
Pulse outputs: Signalization | Frequency: wN ~ f = 0 … fmax; fmax = 10 … 100 Hz Optional: 1 pulse/1 m3; 1 pulse/0.1 m3; 1 pulse/0.01 m3 (max. 100 pulses/s) |
Pulse outputs: Technology | 1. Highside-driver (PNP, open collector) at protected supply voltage; not galvanically isolated) Short-circuit protected (analog): 100 mA High level: > supply voltage - 3 V Leckage current: IOFF < 10 µA 2. Semiconductor relay; output galvanically isolated Output voltage/current: Max. 30 V / 50 mA |
Electrical connection | Plug-in connector M12 (A-coded), male, 8-pin (shielded), screwed ATEX approval only in combination with original cable! |
Maximum cable length | Voltage interface / current interface / pulse outputs: 100 m Voltage mode: Use AGND and RL ≥ 10 k (mass offset) |
Mounting position | Arbitrary (exception: Temperature element may never be placed “above” heater element) |
Mounting tolerance | ±3° relative to flow direction (unidirectional) |
Minimum immersion depth | DN40 |
Protection type | Sensor probe: IP67; enclosure: IP65 (with correctly attached cable) |
Protection class | III (PELV) |
ATEX-Declaration | Gas (zone 2): II 3G Ex ec ic IIC T4 Gc Dust (zone 22): II 3D Ex ic tc IIIC T135°C Dc |
Probe length | Compact version: 250/600 mm Remote version: Probe 250/600 mm; cable: 1 … 10 m (step: 1 m) |
Weight | Approx. 500 g max. |
1) Standard conditions: TN = 20 °C and pN = 1,013.25 hPa
2) Related to adjustment reference; "fmr" = final measuring range
Subject to technical changes.