SCHMIDT® Mass Flow Sensor IL 30.208 and IL 30.212 Mini-IL

SCHMIDT® Mass Flow Sensor Mini-IL with integrated measuring transmitter

 

  • Measurement of mass flow directly at the machine or tool
  • Low pressure loss
  • Simple installation using standard pips or push-in fittingfor pneumatic hose connections
  • Analogue output (4 … 20 mA)
  • Digital output (Modbus RTU) also available
  • Pressure resistant up to 8 bar

Available versions:

  • IL 30.208 (G 1/4): 3 measuring ranges (20 / 100 / 200 Norm-l/min)
  • IL 30.212 (G 3/8): 2 measuring ranges (300 / 500 Norm-l/min)

 

Perfect for use in air consumption, air and gases flow measurement, as well as for compressed air operated tools and machines.

 

Flow rate volumes of gases – an important parameter in industrial processes

 

Actions to save energy and to assure quality in the production process are of particular importance in industrial processes. The ability to measure volumetric flow rates and volumetric flow of gases precisely is essential for this purpose. The requirements imposed on the flow sensor used for this are demanding: the sensor has to be capable of delivering precise measurements for different gases, at high overpressures and across a wide range of temperatures.

 

A further consideration when selecting a flow sensor is the required maintenance and associated costs. The SCHMIDT® InLine Mass Flow Sensor Mini-IL is a low-maintenance flowmeter offering accurate and reliable measurements even in long-term installations.

 

The “true professional“ for industrial processes and compressed air technology

 

The thermal SCHMIDT® Mass Flow Sensor Mini-IL is the perfect solution for demanding industrial applications. It can be used for a diverse range of applications, such as compressed air monitoring directly at the machine or tool, consumption recording of gases and a great deal more.

 

Thanks to its DN 8 and DN 12 connection sizes particularly low mass flowrates can be monitored. The Mini-IL is pressure-resistant up to 8 bar overpressure as standard.

 

This sensor is very easy to install: mount the sensor using the available measuring section pipes or push-in fittings for pneumatic hose connections and connect it electrically – then you are ready to go!

 

This sensor operates without any moving parts and employs a measuring principle that eliminates any drift or signs of ageing. This reduces the required sensor maintenance to an absolute minimum.

 

To activate and program the Modbus function, an Interface Splitter IL 30.2xx and a PC Programming Kit are necessary (accessory).

 

SCHMIDT Technology – Simply a question of better measurement

Specifications

Technical data
Technology designThermal InLine Mass Flow Sensor
Measuring range VNIL 30.208: 0.2 … 20 Norm-l/min; 1 … 100 / 200 Norm-l/min
IL 30.212: 3 … 300 / 500 Norm-l/min
Lower detection limit VNIL 30.208: 0.2 resp. 1 Norm-l/min
IL 30.212: 3 Norm-l/min
Measuring range TM-20 … +60 °C
Measuring directionUnidirectional
Measured mediumClean (compressed) air or nitrogen; other gases on request
(fluid group 2 according PED 2014/68/EU)
Measuring quantityStandard mass flow VN1)
Temperature of medium TM (only with digital output)
Measuring accuracy
Measuring accuracy VN±(3 % of measured value + 0.3 % of fmr) 2)
With higher volume flows (> 50 % of fmr) an operating pressure > 3 bar is recommended for optimal measuring results
Response time (t90) VNApprox. 10 s
Temperature of medium TM±2K ( (VN > 2 % of measuring range)
Operating temperature
Sensor-20 … +60 °C (-10 … +60 °C when push-in fittings for pneumatic hose connections are used)
General data
HumidityMeasuring mode: Non-condensing (< 95 % RH)
Operating pressure8 bar (overpressure)
Supply voltage24 V DC ± 10 %
Current consumptionTyp. 25 mA / max. 100 mA
Analog output (order option)1 x 4 … 20 mA (VN)
Digital output (order option)Modbus RTU (VN and TM) resp. Module interface incl. analogue output 1 x 4 … 20 mA (VN)
Electrical connectionAnalogue version: Connection cable, pigtail, 4 x 0.14 mm², 2 m long
Digital version: Connection cable, 0.2 m long, M12 connector 8-pole
Cable: PVC grau, outer Ø 3.8 mm
Length of connection cablemax. 100 m (recommended; take care of wire resistance)
Mounting positionArbitrary
InstallationInner threads DN8 or DN12 (G1/4 and G 3/8): Measuring section pipes or push-in fittings for pneumatic hose connections are incl.
Protection typeIP64 (housing)
Protection classIII (SELV or PELV)
Dimensions (L x W x H)IL 30.208: 37 x 30 x 81 mm (without pipes / push-in fittings)
IL 30.212: 42 x 30 x 84 mm (without pipes / push-in fittings)
Material
EnclosuePBT
FixtureBrass, nickel-plated
Tube bodyStainless steel

1) Standard conditions: TN = 20 °C and pN = 1,013.25 hPa

2) Related to adjustment reference; "fmr" = full measuring range

Subject to technical changes.

Order information

Order information SCHMIDT® InLine Mass Flow Sensor Mini-IL
 DescriptionArticle-Number
Basic sensorSCHMIDT® InLine Mass Flow Sensor IL 30.208
VN; 8 bar; 3 % class; DN 8 / G 1/4
572900ABCD
 Options 
TypeStandard 1   
Mechanical type2 measuring section tubes (length 100 mm, thread R1/4 on both sides; not fitted)  1  
2 push-in fittings for pneumatic hose connection (hose outer diameter 12 mm, fitted, field of application -10 … +60 °C)  2  
Measuring rangeMeasuring range 0.2 … 20 Norm-l/min   1 
Measuring range 1 … 100 Norm-l/min   2 
Measuring range 1 … 200 Norm-l/min   3 
Output signalAnalogue output 1 x 4 … 20 mA (VN; with 2 m fixed cable, open cable ends)    1
Digital output (Modbus RTU [VN and TM] resp. module interface incl. analogue output 4 … 20 mA [VN]; 0.2 m cable with M12 connector, 8-pole)    2
 DescriptionArticle-Number
Basic sensorSCHMIDT® InLine Mass Flow Sensor IL 30.212
VN; 8 bar; 3 % class; DN 12 / G 3/8
572901ABCD
 Options 
TypeStandard 1   
Mechanical type2 measuring section tubes (length 150 mm, thread R3/8 on both sides; not fitted)  1  
2 push-in fittings for pneumatic hose connection (hose outer diameter 12 mm, fitted, field of application -10 … +60 °C)  2  
Measuring rangeMeasuring range 3 … 300 Norm-l/min   1 
Measuring range 3 … 500 Norm-l/min   2 
Output signalAnalogue output 1 x 4 … 20 mA (VN; with 2 m fixed cable, open cable ends)    1
Digital output (Modbus RTU [VN and TM] resp. module interface incl. analogue output 4 … 20 mA [VN]; 0.2 m cable with M12 connector, 8-pole)    2
 Standard Factory Calibration CertificateArticle-Number
Calibration CertificateFactory Calibration Certificate IL 30.208on request
Factory Calibration Certificate IL 30.212on request

Accessories

Connection technology

DescriptionArticle-Number
Power supply unit: output 24 V / 1A DC, supply voltage 115/230 V AC (strip terminal)535 282

Measured value display

DescriptionArticle-Number
LED display MD 10.010 in wall housing to show volume flow and flow velocity, 85 … 250 V AC and sensor power supply527 320
LED-display MD 10.010; as with 527 320 but with 24 V DC voltage supply 527 320, with a 24 V DC power supply528 240
LED display MD 10.015, similar to 527 320 but with an additional sum function and a second measuring input527 330
LED display MD 10.015, similar to 527 330 but with 24 V DC voltage supply528 250
Measuring value module MD 10.020, 7-Segment-Display, incl. 0.6 m connection cable to connect to the module plug554 900
Assembly kit for pipe assembly suitable for MD 10.010/10.015, including pipe clamps and collar for adjustment for the pipe diameter531 394

Miscellaneous

DescriptionArticle-Number
Factory calibration certificate for IL 30.208on request
Factory calibration certificate for IL 30.212on request
SCHMIDT® PC Programming Kit; Adapter (USB / M12, 5-pole), USB stick (Sensor App PC, driver; for PC, laptop, notebook; Windows)564 710
Datalogger DL 10.010569 300
SCHMIDT® Bluetooth® Module BT 10.010560 500
SCHMIDT® Sensor App (Android): free of charge download at "Service & Support" – SensorsDownload
SCHMIDT® Interface Splitter IL 30.2xx (Mini-IL) configuration 1 (Y splitter only)on request
SCHMIDT® Interface Splitter IL 30.2xx (Mini-IL) configuration 1 (Y splitter + plug-in power supply)on request

Downloads

Back to Top