e-Mail to SCHMIDT Technology

Strömungssensoren
 

SCHMIDT® Flow Sensors for Compressed Air

For measurements in compressed air systems the thermic SCHMIDT® Flow Sensors provide many benefits:

  • Direct detection of norm flow velocity independent of pressure and temperature
  • For tube diameters DN 15 ... DN 1.000
  • Installation and removal during production and under pressure possible
  • Very high flow velocities up to 200 m/s (also for undersized tubes)
  • Very small measuring range limit of 0.2 m/s for detection of leakage

 

Which sensor is suitable for which application?
For measurements in compressed air systems either Insertion- or Inline-sensors can be used.

Application examples:

Accounting and contracting

  • Measurement of compressed air consumption

Saving of energy and efficiency through

  • Detection of leakages
  • Optimal compressor controlling

Plant and machine monitoring

  • Avoid production loss
  • Optimizing processes
  • Perform-conditioned maintenance

 

 
   
Application Report
- Compressed air
 
Flow Calculator  
SCHMIDT® LED-Messwertanzeige MD 10.010/10.015
SCHMIDT® LED measured value display MD 10.010/10.015
 
  SS 20.60 SS 20.261 SS 30.300
Product code SS 20.60 SS 20.261 SS 30.300 … 30.303
Sensor type Insertion sensor Insertion sensor Inline-Sensor
Tube diameter DN 25 – DN 800 DN 25 – DN 600 with integrated probe tube
DN 15 / 25 / 40 / 50
Max. volume flow m³/h 500.000 (DN 800) 74.300 (DN 700) 75 / 228 / 417 / 712
Max. pressure 16 bar 8 bar 16 bar
Display 4-point LED or external
LED-display (SS 20.031)
1 green LED,
1 red LED
Integrated LED-display
Working temperature -20 … +80 / 120 °C -20 … +85 °C 0 … +60 °C
Output signals 1 x 0 ...10 V or 0/4 … 20 mA
(selectable at order)
1 x impulse output
4 … 20 mA 1 x 4 … 20 mA or switching output
1 x switch-/Impulse output
Supply voltage 24 V DC ± 20 % 24 V DC ± 20 % 24 V DC ± 20 %
Datenschutz